What this study is
The primary objective of ARISE II is to assess the safety and effectiveness of the GORE® Ascending Stent Graft device in the treatment of lesions involving the ascending aorta and aortic arch.
What's being tested
- GORE® Ascending Stent Graft (ASG device)
Intervention · DEVICE
Endovascular aortic repair of the ascending aorta
- GORE® Thoracic Aortic Graft Thoracic Branch Endoprosthesis (TBE Device)
Intervention · DEVICE
Endovascular aortic repair of the ascending aorta/aortic arch
- Surgery
Intervention · PROCEDURE
Open surgical repair of the ascending aorta and/or the aortic arch
Study details
- Official title
- Evaluation of the GORE® Ascending Stent Graft in the Treatment of Lesions of the Ascending Aorta
- Sponsor
- W.L.Gore & Associates
- Conditions
- Aortic Aneurysm, Thoracic · Pseudoaneurysm · Aortic Dissection · Aorta; Lesion
- Enrolling
- 370 people
- Starts
- 2023-11-28
- Est. completion
- 2034-01
- Design
- Open-label, non-randomized, parallel groups
- Record
- View on ClinicalTrials.gov ↗
Who can join
Age 18 Years and overSex ALLHealthy volunteers Not acceptedYou may qualify if
- ASG Device Alone Arm The patient is/has: Ascending Aortic pathologies warranting surgical repair compatible with the treatment requirements of the ASG device meeting any of the following criteria: Aneurysm; Fusiform aneurysm (≥50mm or documented growth rate >0.5cm/year); Saccular aneurysm (no diameter criteria); Pseudoaneurysms (>30 days post-surgery, no diameter criteria) Non-aneurysm; Penetrating Aortic Ulcers (PAUs) (no diameter criteria); Pseudoaneurysms, following open surgical repair of a Type A dissection (>30 days post-surgery, no diameter criteria)
- Anatomic compatibility with ASG device based on Gore Imaging Sciences review.; Treatment must be limited to the ascending aorta; Lesion location is ≥2cm distal to the most distal coronary artery ostia; Distal extent of the lesion is located ≥2cm proximal to the origin of the Brachiocephalic Artery (BCA); Proximal and distal landing zones must be ≥2cm in length; Landing zones cannot be heavily calcified, or heavily thrombosed; Landing zone diameter between 27mm - 48mm; For patients with prior replacement of the ascending aorta and/or aortic arch by an endovascular or surgical graft, there must be at least ≥2 cm overlap of ASG device and previously implanted graft.
- Considered high-risk for open surgical repair by meeting any of the following criteria:; ≥75 years of age; Previous median sternotomy; Documented identification of other subject-specific risk factors (e.g., medical history, active medical diagnosis) by a study investigator and an experienced open ascending and/or aortic arch surgeon (e.g., cardiothoracic surgeon).
- Age ≥18 years at time of informed consent signature
- Adequate vascular access via transfemoral or retroperitoneal approach
- Informed Consent Form (ICF) signed by the subject or legally authorized representative
- Agrees to comply with protocol requirements, including imaging and 5-year follow-up
- ASG + TBE Device Arm The patient is/has: Ascending and/or Arch Aortic pathologies warranting surgical repair compatible with the treatment requirements of the ASG device and meeting any of the following criteria: Aneurysms; Fusiform aneurysm (≥55 mm or documented growth rate >0.5cm/year); Saccular aneurysm (no diameter criteria); Pseudoaneurysms (>30 days post-surgery, no diameter criteria) Non-aneurysms; Penetrating Aortic Ulcers (no diameter criteria); Pseudoaneurysms, following open surgical repair of a Type A dissection (>30 days post-surgery, no diameter criteria); Chronic de novo (>90 days) Type A aortic dissection requiring treatment; Chronic de novo aortic dissection with primary entry tear in the ascending aorta or arch; Chronic de novo aortic dissection with primary entry tear in the descending thoracic aorta with retrograde involvement of the aortic arch and/or ascending aorta; Residual aortic dissection following surgical repair of Type A aortic dissection requiring treatment (>30 days post-surgery)
- Anatomic compatibility with ASG device used in combination with the TBE Device based on Gore Imaging Sciences review. Proximal Aortic Landing Zone:; Landing zone is native aorta or surgical graft; Lesion location is ≥2cm distal to the most distal coronary artery ostia; Proximal landing zone must be ≥2cm in the ascending aorta.; Landing zone cannot be aneurysmal, heavily calcified, or heavily thrombosed; Landing zone diameter between 27mm - 48mm; Acceptable proximal landing zone outer curvature length for the required device Branch Vessel Landing Zone:; Length of ≥2.5 cm proximal to first major branch vessel; Target branch vessel inner diameters of 11-18 mm; Target branch vessel landing zone must be in native vessel that cannot be heavily calcified, or heavily thrombosed Distal Aortic Landing Zone:; Outer curvature must be ≥2 cm proximal to the celiac artery; Aortic inner diameters between 16-42 mm; Landing zone in native aorta or previously implanted GORE® TAG® Conformable Thoracic Stent Graft (CTAG Device)
- Considered high-risk for open surgical repair by meeting any of the following criteria:; ≥75 years of age; Previous median sternotomy; Documented identification of other subject-specific risk factors (e.g., medical history, active medical diagnosis) by a study investigator and an experienced open ascending and/or aortic arch surgeon (e.g., cardiothoracic surgeon).
- Age ≥18 years at time of informed consent signature
- Adequate vascular access via transfemoral or retroperitoneal approach
- Informed Consent Form (ICF) signed by the subject or legally authorized representative
- Agrees to comply with protocol requirements, including imaging and 5-year follow-up
- Surgical Follow-up Cohort Subjects who meet the following criteria will be followed:; The aortic lesion involves the ascending aorta and/or aortic arch; The subject is determined to be high-risk for open surgical repair per the protocol requirements; The subject is at least 18 years of age; The subject is willing to comply with the protocol requirements; Open surgery to repair the aortic lesion the patient was screened for is intended to be performed at the investigational site responsible for initiating the screening process for the study
You can't join if
- ASG Device Alone Arm The patient is/has: De novo Type A dissection
- Requires immediate treatment
- Dissected great vessels requiring treatment
- Anticipated need for coronary or aortic valve intervention within one year post treatment
- Any aortic valve repair or replacement including transcatheter aortic valve replacement (TAVR) or coronary artery intervention within 30 days prior to treatment
- Complex percutaneous coronary intervention (PCI) or treatment for acute coronary syndrome requiring Dual Anti Platelet Therapy (DAPT) within 30 days prior to treatment
- Open chest surgical repair within 30 days prior to treatment
- Presence of Intramural Hematoma (IMH) in landing zones
- Prosthetic heart valve in the aortic position that precludes safe delivery of the ASG device
- Aortic insufficiency grade 3 or greater
- Previous endovascular repair with a non-Gore device that would interfere with or result in contact with planned repair
- Concomitant vascular disease requiring treatment that is not planned for index endovascular procedure
- Any stroke or myocardial infarction within 6 weeks prior to treatment
- Presence of protruding and/or irregular thrombus and/or atheroma in the ascending aorta or aortic arch or any other factors that could increase the risk of stroke based on imaging review
- Known degenerative connective tissue disease (e.g., Marfan's or Ehler-Danlos Syndrome, EDS)
- Participation in investigational drug or medical device study within one year of enrollment unless approved by the sponsor
- Known history of drug abuse within one year of treatment
- Pregnant at time of procedure
- Active infected aorta, mycotic aneurysm
- Active systemic infection (e.g., infection requiring treatment with parenteral anti-infective medication)
- Renal failure, defined as patients with an estimated Glomerular Filtration Rate (eGFR) <30 (mL/min/1.73 m2) or currently requiring dialysis
- Life expectancy <12 months
- Known sensitivities or allergies to the device materials
- Known hypersensitivity or contraindication to anticoagulants or contrast media, which is not amenable to pre-treatment
- Body habitus or other medical condition which prevents adequate fluoroscopic and CT visualization of the aorta
- ASG + TBE Device Arm The patient is/has: Acute and subacute de novo Type A dissection (defined as <90 days)
- Requires immediate treatment
- Dissected great vessels requiring treatment
- Anticipated need for coronary or aortic valve intervention within one year post treatment
- Any aortic valve repair or replacement including transcatheter aortic valve replacement (TAVR) or coronary artery intervention within 30 days prior to treatment
- Complex percutaneous coronary intervention (PCI) or treatment for acute coronary syndrome requiring Dual Anti Platelet Therapy (DAPT) within 30 days prior to treatment.
- Open chest surgical repair within 30 days prior to treatment
- Presence of Intramural Hematoma (IMH) in landing zones
- Prosthetic heart valve in the aortic position that precludes safe delivery of the ASG device
- Aortic insufficiency grade 3 or greater.
- Previous endovascular repair with a non-Gore device that would interfere with or result in contact with planned repair
- Concomitant vascular disease requiring treatment that is not planned for index endovascular procedure
- Any stroke or myocardial infarction within 6 weeks prior to treatment
- Presence of protruding and/or irregular thrombus and/or atheroma in the ascending aorta or aortic arch or any other factors that could increase the risk of stroke based on imaging review
- Known degenerative connective tissue disease (e.g., Marfan Syndrome or Ehlers-Danlos Syndrome, EDS)
- Participation in investigational drug or medical device study within one year of enrollment unless approved by the sponsor
- Known history of drug abuse within one year of treatment
- Pregnant at time of procedure
- Active infected aorta, mycotic aneurysm
- Active systemic infection (e.g., infection requiring treatment with parenteral anti-infective medication)
- Renal failure, defined as patients with an estimated Glomerular Filtration Rate (eGFR) <30 (mL/min/1.73 m2) or currently requiring dialysis
- Life expectancy <12 months
- Known sensitivities or allergies to the device materials
- Known hypersensitivity or contraindication to anticoagulants or contrast media, which is not amenable to pre-treatment
- Body habitus or other medical condition which prevents adequate fluoroscopic and CT visualization of the aorta
- Previous instance of Heparin Induced Thrombocytopenia type 2 (HIT-2) or known hypersensitivity to heparin or a history of a hypercoagulability disorder and/or state
Sign in and we'll check these against your records.Full criteria on ClinicalTrials.gov ↗
Loading treatment details…
Study locations (41)
41 openUniversity of Alabama at Birmingham
Birmingham, Alabama, United States
MemorialCare Heart and Vascular Institute - Long Beach Medical Center
Long Beach, California, United States
Keck Medical Center University of Southern California, HCC II
Los Angeles, California, United States
Cedars Sinai Medical Center
Los Angeles, California, United States
Stanford Hospital
Stanford, California, United States
University of Colorado Hospital Authority
Aurora, Colorado, United States
Hartford Hospital
Hartford, Connecticut, United States
MedStar Washington Hospital Center
Washington D.C., District of Columbia, United States
University of Florida - Gainesville
Gainesville, Florida, United States
University of South Florida
Tampa, Florida, United States
Emory University Hospital
Atlanta, Georgia, United States
Northwestern University -Bluhm Cardiovascular Institute, Clinical Trials Unit
Chicago, Illinois, United States
Indiana University School of Medicine
Indianapolis, Indiana, United States
University of Maryland Medical Center
Baltimore, Maryland, United States
Massachusetts General Hospital
Boston, Massachusetts, United States
University of Michigan Frankel Cardiovascular Center
Ann Arbor, Michigan, United States
Corewell Health
Grand Rapids, Michigan, United States
Mayo Clinic - Rochester
Rochester, Minnesota, United States
Washington University School of Medicine - St. Louis
St Louis, Missouri, United States
Hackensack UMC
Hackensack, New Jersey, United States
Westchester Medical Center
Valhalla, New York, United States
University of North Carolina at Chapel Hill
Chapel Hill, North Carolina, United States
Atrium Health
Charlotte, North Carolina, United States
Duke University Medical Center
Durham, North Carolina, United States
Cleveland Clinic Foundation
Cleveland, Ohio, United States
OhioHealth Research and Innovation Institute
Columbus, Ohio, United States
Oregon Health and Science University
Portland, Oregon, United States
University of Pennsylvania
Philadelphia, Pennsylvania, United States
University of Pittsburgh Medical Center
Pittsburgh, Pennsylvania, United States
Lankenau Institute for Medical Research
Wynnewood, Pennsylvania, United States
Medical University of South Carolina
Charleston, South Carolina, United States
Cardiothoracic and Vascular Surgeons
Austin, Texas, United States
Methodist DeBakey Heart & Vascular Center
Houston, Texas, United States
The Heart Hospital at Baylor Plano
Plano, Texas, United States
Intermountain Heart Institute
Murray, Utah, United States
Inova Fairfax Medical Campus
Falls Church, Virginia, United States
Sentara Mid Atlantic Cardiothoracic Surgeons
Norfolk, Virginia, United States
University of Washington Medical Center
Seattle, Washington, United States
West Virginia University Medicine
Morgantown, West Virginia, United States
University of Wisconsin Hospital & Clinics
Madison, Wisconsin, United States
Medical College of Wisconsin
Milwaukee, Wisconsin, United States
Study team
Sponsor
W.L.Gore & Associates
Study ID ASG 22-02
Principal investigator
Eric Roselli, MD
The Cleveland Clinic
Frequently asked questions
The sponsor hasn't published answers to common questions for this trial.