What this study is
Six patients with diagnosed bone loss of the hip who have consented to minimally invasive repair will be approached to participate in the study. Participants will have the liquid portion of bone marrow collected using the Zimmer Biomet Biocue system, which is the standard system used by physicians at The Ohio State University, and the novel Marrow Cellutions system™. Bone marrow liquid will be collected from the surgical hip using the Zimmer Biomet Biocue system, and the Marrow Cellutions system™ will be used to collect bone marrow liquid from the non-surgical hip. Following collection, the bone marrow liquid will be processed using the respective systems to concentrate the cells and molecules found in the bone marrow liquid. As part of the standard of care for this arthroscopic procedure, concentrated bone marrow liquid processed using the Zimmer Biomet Biocue system will be delivered to the surgical site as an adjunct to promote healing. Concentrated bone marrow liquid prepared with the Zimmer Biomet Biocue system is given as part of the standard of care for patients undergoing minimally invasive treatment for bone loss of the hip; therefore, the target population for this study are individuals between the ages of 18-50 years with confirmed bone loss of the hip who have consented to minimally invasive repair. In addition to the concentrated bone marrow liquid prepared using the Zimmer Biomet Biocue system, patients will also have bone marrow liquid collected from the non-surgical hip using the Marrow Cellutions™ system. Only concentrated bone marrow liquid produced with the Zimmer Biomet Biocue system will be given to the patient. All concentrated bone marrow liquid produced with the Marrow Cellutions™ system will be sent to the laboratory for analysis. Additionally, white blood cells will be concentrated into an autologous protein solution (APS) using the Zimmer Biomet Plasmax system from blood collected using a routine blood draw. All protein solution produced will be sent to the laboratory for analysis. No protein solution will be given to the patient. As the bone marrow liquid collection using the Marrow Cellutions™ system and the blood draw to produce protein solution using the Zimmer Biomet Plasmax system are being performed for research,
What's being tested
- Bone Marrow Collection
Intervention · DEVICE
Comparing the two collection systems for bone marrow aspirate
Study details
- Official title
- Comparison of the Constituents of Bone Marrow Aspirate and Autologous Protein Solution Collected With a Traditional and a Novel System
- Sponsor
- Ohio State University
- Conditions
- Hip Arthropathy · Avascular Necrosis of Bone · Subchondral Cysts
- Enrolling
- 6 people
- Starts
- 2024-03-25
- Est. completion
- 2026-12-31
- Design
- Open-label, single group
- Record
- View on ClinicalTrials.gov ↗
Who can join
Age 18 Years – 50 YearsSex ALLHealthy volunteers Not acceptedYou may qualify if
- Patients aged 18 - 50
- Patients undergoing hip arthroscopy for subchondral bone cysts and/or avascular necrosis
You can't join if
- Patients with a history of hematologic issues including anemia and sickle cell anemia
- Patients with a history of leukemia, lymphoma, or other bone marrow related diseases
- Patients with diabetes
- Patients with a history of bone marrow aspirate
Sign in and we'll check these against your records.Full criteria on ClinicalTrials.gov ↗
Loading treatment details…
Study locations (1)
1 openJameson Crane Sports Medicine Institute
Columbus, Ohio, United States
- Michael Keller · Contact614-293-2410michael.keller@osumc.edu
- Karen Persons · Contactandrea.persons@osumc.edu
- William K Vasileff, MD · Principal investigator
Recruiting
Study team
Sponsor
Ohio State University
Study ID 2023H0351
Principal investigator
William K Vasileff, MD
Ohio State University
Frequently asked questions