What this study is
The study will use a PET-based measure of brain cell (neuron) connections (synapses) in young adults who have also obtained an MRI, to assess how the loss of brain cell connections (synaptic pruning) is captured by MRI-based measures. This will inform youth MRI studies to understand neurotypical brain development that can help identify abnormal trajectories as in mental illness.
What's being tested
- PET Imaging Scan using [11C]UCB-J
Intervention · RADIATION
[11C]UCB-J (~ 15 mCi and ≤ 6μg) will be injected as a slow intravenous bolus. Following an intravenous bolus injection of [11C]UCB-J, the participants will be positioned in the scanner for a low dose CT scan (for attenuation correction) fifty-five minutes after the [11C]UCB-J injection, and emission data will be collected.
Study details
- Sponsor
- Beatriz Luna
- Conditions
- Healthy Adult Participants · Synaptic Plasticity
- Enrolling
- 60 people
- Starts
- 2026-01-09
- Est. completion
- 2028-06-30
- Design
- Open-label, single group
- Record
- View on ClinicalTrials.gov ↗
Who can join
Age 18 Years and overSex ALLHealthy volunteers AcceptedYou may qualify if
- Males or females between 18-26 years of age, AND currently enrolled in the Parent Project (R01MH067924)
You can't join if
- (these exclusion criteria are outlined in the Parent Project)
- Head injury with loss of consciousness over an hour.
- A vision problem or eye movement problem (such as lazy eye, double vision, blurred vision, or color blindness).
- A learning disability and/or ever had an Individualized Education Plan (IEP) in school.
- Significant neurological or metabolic illness: Epilepsy, Meningitis, Encephalitis, Diabetes, Huntington's disease.
- Diagnosed with a psychiatric disorder.
- Participants with, or with a first degree relative, having a DSM IV Axis l psychiatricdisorder.
- Metal implants or ferromagnetic objects contained within the body which may interfere with the MRI scan (but not limited to, those with a pacemaker, presence of metallic fragments near the eyes or spinal cord, or cochlear implant.) Dental fillings do not present a risk for MRI. If there is a possibility of metal being present in the participant's body, the participant will be excluded from the study.
- Weight more than 250 pounds.
- Claustrophobia or uncomfortable in small spaces.
- <70% on the Achenbach scale (either from Youth Self Report (YSR) or Adult Self Report (ASR)).
- IQ < 80 or IQ > 130.
- Pregnancy or lactation, lack of effective birth control during 15 days before the scans.
- Currently employed as radiation worker; or participation in radioactive drug research protocols within the previous year such that the total cumulative annual radiation dose (i.e., from participation in the previous radioactive drug study [studies] and this study) would exceed the radiation dose limits specified in the FDA regulations (i.e., 21 CFR 361.1) that govern the research use of [C-11]UCB-J
- History of drug or alcohol abuse (from parent study eligibility).
Sign in and we'll check these against your records.Full criteria on ClinicalTrials.gov ↗
Loading treatment details…
Study locations (1)
1 openLaboratory of Neurocognitive Development
Pittsburgh, Pennsylvania, United States
Study team
Sponsor
Beatriz Luna
Study ID STUDY24060023
Principal investigator
Beatriz Luna, PhD
University of Pittsburgh
Frequently asked questions
The sponsor hasn't published answers to common questions for this trial.